Description
The Spirax Sarco SX90 Process Controller is a 1/8 DIN panel mounted controller for constant set point control with fixed preset fixed point systems. The controller has a wide range of inputs and outputs to control industrial processes using PID, and can be used with Spirax Sarco's pneumatically operated motorized control valves, electronic and electrical equipment.
specificities
- General purpose inputs: RTD, thermocouple, mA and mV.
- General purpose outputs: VMD (valve motor drive), continuous mA and voltage, relays for on/off control, and logic signals.
- Auxiliary power supply: for external transmitters requiring 24VDC.
- Setpoints: can be set locally, remotely, or selected from 4 setpoints.
- Slope: The rate of change from one setpoint to another with two separate slopes (slope up or slope down).
- Remote Setpoint: For serial control (master/slave) of two controllers, or remote setpoint control.
- Retransmission function: for retransmission of the process value or setpoint, or as a second analog output.
- Event alarms: 4 programmed relay outputs for deviation, zone and process value alarms.
- Quick Code: With a 5-digit quick code, the controller can be easily installed and debugged.
- Serial communication: Up to 64 controllers can be connected to the management system through the serial port RS485 (5 wires).
- Auto/Manual: Automatic mode and manual mode can be switched via keypad or logic input.
- Logic Inputs: 3 logic inputs provide a variety of selection functions.
- Potentiometer input: for feedback of valve position.
- Text message: can be set to scroll text message, can remind the user of the process status.
- Forced Output: The forced output level is determined by the instrument parameters and can be activated by a logic input or by writing a parameter.
accreditation
- Conforms to 93/68/EEC in accordance with EN61010-1:90 for the necessary protective conditions for electrical equipment.
- EMC emission standard: EN 61326-1: 1997 Class B (including amendments A1, A2 and A3).
- EMC Immunity Standard: EN 61326-1: 1997 Industrial locations (including amendments A1, A2 and A3).
Technical Parameters
Overall technical parameters
sports event |
particulars |
mounting |
Panel Mount 1/8 DIN |
Supply power |
85 - 265Vac, 9W max. |
electrical connection |
screwed end |
Packaging grade |
IP65 - Plugged in from front panel, NEMA 4X |
Working temperature and humidity |
Temperature 0 - 55°C, Humidity 5% - 85% |
matrix |
Cannot be used in explosive or corrosive environments |
Electromagnetic Compatibility (EMC) |
EN 61326 |
Electrical Safety BS EN 61010 |
Installation category II |
weights |
350 grams |
accreditation |
CE |
Process Variable Inputs
sports event |
particulars |
Calibration accuracy |
< ± 0.25% (± 1 lowest significant digit LSD) |
resolution (of a photo) |
<0.5μV (1.6s filter) |
Input Filtering |
Close to 59.9s |
RTD |
3-wire PT100, DIN43760 |
Indicator current |
0.2mA |
General purpose linear mA |
4 - 20mA, 0 - 20mA using external shunt resistor 2.49Ω |
Linear Input Range |
-10 - 80mV |
thermocouples |
K, J, N, R, S, B, L, T, C, Customized |
sampling frequency |
4Hz (250ms) |
Cold End Accuracy |
< ± 1°C at 25°C ambient temperature |
Linear mA accuracy |
<0.1% readings |
Input Impedance |
100MΩ |
Number of setpoints |
3 points plus remote setpoint |
user calibration |
Two-point gain and offset |
Transmitter Power Supply
sports event |
particulars |
isolate |
300Vac double insulation |
output voltage |
18V ± 15% |
amps |
30mA max. |
Load regulation |
<1V, 25mA |
control
sports event |
particulars |
scale band |
1 - 9999 engineering units, 0.01 - 300, 0.1 - 3000 |
Points time |
Close - 9999 |
differentiation time |
Close - 9999 |
error band |
One-time tuning or intrinsic frequency tuning. The controller will automatically select the best method depending on the process conditions. |
auto-tuning |
Lag 0.01 - 300.0 or 0.1 - 3000 engineering units |
switching control |
1 - 9999 engineering units, 0.01 - 300, 0.1 - 3000. |
abate |
Overshooting is minimized during critical processes. |
Auto/Manual Mode |
Selection from the keyboard |
Relay insulation |
300Vac double insulation |
Logic inputs (x3) |
|
electrocution closure |
Open >1200R, Close <300R |
Communication insulation |
300Vac double insulation |
software |
EIA 485 5-wire (EIA 422 compliant) |
protocols |
Modbus RTU Slave |
Remote setpoint input
sports event |
particulars |
isolate |
300Vac double insulation |
Calibration accuracy |
< ± 0.25% (± 1 lowest significant digit LSD) |
sampling frequency |
4Hz (250ms) |
resolution (of a photo) |
>14bits - 0.5mV (0 - 10V input), 2μV (4 - 20mA) |
Input Impedance |
>222KΩ (voltage), >2.49Ω (current) |
Linear Input Range |
0 - 10V, 0 - 20mA |
Input Filtering |
Close - 59.9s |
zero offset |
Full range of user adjustments |
user calibration |
Two-point gain and offset |
Potentiometer Input
sports event |
particulars |
Potentiometer resistance range |
100 - 10kΩ |
excitation voltage |
0.46 - 0.54V |
resolution (of a photo) |
0.006% range (greater than 14Bits) |
sampling rate |
1Hz |
Short Circuit Potentiometer Detection |
<25Ω |
Open Potentiometer Detection |
>2MΩ |
Open Arc Brush Detection |
>5MΩ |
Contact class |
Maximum 2A at 264Vac resistor 2A current. (2A max for AB terminals). |
exports
sports event |
particulars |
Output 1 |
SPST normally open contact |
Output 2 |
0 - 20mA, 4 - 20mA, 300Vac double insulated, 13.5bits resolution (<550Ω) |
Output 3 |
0 - 20mA, 4 - 20mA, 300Vac double insulated, 13.5bits resolution (<550Ω) |
Output 4 |
Completely changed relay contacts |
Outputs 5 and 6 (VMD) |
2 SPST interlocking normally open contacts |
Input Filtering |
Close to 59.9s |
zero offset |
Full range of user adjustments |
user calibration |
Two-point gain and offset |
Open Arc Brush Detection |
>5MΩ |
Wiring Instructions
The installation and commissioning instructions supplied with the unit stipulate that safe operation of the controller can only be guaranteed by proper installation, commissioning, use and maintenance by suitable professionals. It is the responsibility of the company's safety personnel to ensure that the product parameters and safety information in the installation and commissioning instructions are understood and observed.